Fee
| Component | Value |
|---|---|
| Provider fee | $690.25 |
Schedule and sources
- Fee edition
- October 1, 2026
- Record effective
- 2026-04-01
- Schedule edition
- July 22, 2026; effective July 1, 2026
- Official files
- Fee masterSchedule PDFOntario source page
- with the use of an advanced nonfluoroscopic computerized mapping and navigation system ("advanced mapping system") and/or procedure duration >4 hours .................... 690.25 10Passages mentioning Z423
Electrophysiologic Pacing, Mapping and Ablation
Includes percutaneous access, insertion of catheters and electrodes, electrocardiograms,
intracardiac echocardiograms and image guidance when rendered.
# G176 - atrial pacing and mapping ................................................. 334.25
# G177 - ventricular pacing and mapping ........................................ 416.80
# Z423 - with the use of an advanced nonfluoroscopic computerized
mapping and navigation system ("advanced mapping
system") and/or procedure duration >4 hours .................... 690.25 10
Note:
Z423 is only eligible for payment when rendered with G176 or G177.
[Commentary:
1.As of October 2009, the advanced mapping system is typically used in hospital for the
mapping of the following arrhythmias:Electrophysiologic pacing, mapping and ablation
# G178 - catheter ablation therapy.................................................... 352.05
# G179 - repeat pacing, mapping and catheter ablation for additional
distinct arrhythmia(s) without the use of an advanced
mapping system ................................................................. 111.20
Note:
G179 is not eligible for payment with Z423.
# Z424 - transseptal left heart catheterization, with or without
pressure measurements, with or without dye injection....... 297.15 6
Note:
1.Z424 is only eligible for payment when rendered with G176, G177 and/or G178.
2.Z424 is eligible for payment for each transseptal catheter placement to a maximum of 2.
# Z422 - retrograde aortic left heart catheterization with or without
pressure measurement(s) .................................................. 210.55 6
Note:
1.Z422 is only eligible for payment when rendered with G176, G177 and/or G178.
2.Z422 is limited to a maximum of one per electrophysiological pacing, mapping and/or
ablation sitting.
G115 External cardiac pacing (temporary transthoracic) once per 24-
hour period ......................................................................... 46.30
Note:
G115 is not eligible for payment with G521, G522, G523, G395 and G391.
# G366 Testing of arrhythmia inducibility by acute administration of
anti-arrhythmic or adrenergic drugs to a maximum of 2 per
24 hours ............................................................................. 148.50
Note:
G366 is not eligible for payment for the use of isoproterenol for arrhythmia induction when
rendered with G261 and/or G259.
# Z443 Insertion of temporary endocardial electrode ......................... 154.10 6
# Z431 Repositioning of temporary endocardial electrode ................. 64.25 6
Endomyocardial Biopsy
# G288 - transvascular, right or left ................................................... 200.00
Tilt table testing of vasomotor syncope
# G314 - to include arterial cannulation, provocative and blocking
drugs, physician must be continually present..................... 112.00Fee master record
Master, record 7175. Record Layout PDF, page 1.
Z42320260401999999990000690250000003451300000000000000000159600000001596000
Auxiliary master fields are preserved as raw scaled values. The linked layout calls them zero-filled, but this edition contains non-zero values. They are not presented as final dollar fees or PDF units.
| Field | Raw / scale 10,000 |
|---|---|
| provider | 00006902500 / 690.25 |
| assistant | 00003451300 / 345.13 |
| specialist | 00000000000 / 0 |
| anaesthetist | 00001596000 / 159.6 |
| non anaesthetist | 00001596000 / 159.6 |
Explanation
AI-generated. Unreviewed.
Electrophysiology service listed with the use of an advanced nonfluoroscopic computerized mapping and navigation system (advanced mapping system) and/or procedure duration over 4 hours, under Cardiovascular, Electrophysiology/Arrhythmias.
Watch out for
Only eligible for payment when rendered with G176 or G177. G179 is not eligible for payment with Z423.
Report an issue
Something off?
Report an issue with Z423. Do not include patient names, health details or other personal information.