G647

Technical component - 14 or more days recording

Fee

ComponentValue
Provider fee$130.85
Schedule and sources
Fee edition
October 1, 2026
Record effective
2026-04-01
Schedule edition
July 22, 2026; effective July 1, 2026
Official files

PDF page 430 / J16

- technical component - 14 or more days recording ............. 130.85
Passages mentioning G647

PDF page 25 / GP11

Payment for Diagnostic and Therapeutic Services Rendered at a Hospital
  The technical component of a diagnostic and therapeutic service listed below and rendered in a
  hospital is payable at 86.10% of the listed fee in the column headed “T”.
  G104A, G111A, G121A, G127A, G140A, G143A, G146A, G149A, G152A, G153A, G167A,
  G174A,G181A, G209A, G284A, G308A, G310A, G311A, G315A, G414A, G440A, G441A, G442A,
  G443A,G448A, G451A, G455A, G466A, G471A, G519A, G540A, G541A, G542A, G544A, G554A,
  G570A,G574A, G582A, G585A, G647A, G648A, G651A, G652A, G654A, G655A, G682A, G683A,
  G684A,G685A, G686A, G687A, G688A, G689A, G694A, G695A, G815A, G850A, G851A, G852A,
  G853A,G854A, G855A, G856A, G857A, G858A, J301B, J304B, J324B, J327B

PDF page 430 / J16

Level 1
                  Requires a device capable of recording three or more simultaneous channels and the
                  acquisition of a continuous ambulatory electrocardiographic recording of all beats, using three
                  or more skin electrodes. The device must also have the ability to analyze and manually review
                  all parts of the recording, and to produce graphical and quantitative reports of relevant
                  parameters and diagnostic quality tracings for visual review, including post-hoc review of any
                  portion of the recording to enable diagnostic rhythm analysis. Must include a patient diary and
                  event marker capability to enable symptom-rhythm correlation. Minimum 12 hours of
                  monitoring.
               G651 - technical component - 12 to 35 hours recording ................   27.75
               G652 - technical component - 12 to 35 hours scanning.................    38.00
               G650 - professional component - 12 to 35 hours recording ...........                47.90
               G682                       - technical component - 36 to 59 hours recording ................    55.55
               G683                       - technical component - 36 to 59 hours scanning.................     75.95
               G658                       - professional component - 36 to 59 hours recording ...........                    75.45
               G684                       - technical component - 60 hours to 13 days recording........        83.25
               G685                       - technical component - 60 hours to 13 days scanning ........       113.90
               G659                       - professional component - 60 hours to 13 days recording ..                        95.85
               G647                       - technical component - 14 or more days recording .............     130.85
               G648                       - technical component - 14 or more days scanning..............      190.45
               G649                       - professional component - 14 or more days recording ........                    122.25

PDF page 431 / J17

DIAGNOSTIC AND THERAPEUTIC PROCEDURES
 ELECTROCARDIOGRAPHY (ECG)
                                                                                 T         P
          2.Where the duration of the service is more than 36 hours, claims for such services must be
            submitted using the appropriate listed code for that time duration and cannot be submitted
            using multiples of lesser time duration codes.
          3.G647, G648, G649, G694, G695 and G696 are only eligible for payment once per 30 day
            period per patient.
          4.Services related to external cardiac loop recording devices that rely solely on patient
            activation to record electrocardiographic data and do not have the capability of real-time
            rhythm analysis are not insured.
          Medical record requirements:
          In order to demonstrate that payment requirements have been met, all test reports that form
          part of the patient record under this section must include the following information: the number
          of channels recorded, whether the recording was continuous, whether it was analyzed in real
          time, post-hoc or both and other information, such as, the name of the manufacturer and the
          model of the device(s) used in the performance of the test.
Fee master record

Master, record 2307. Record Layout PDF, page 1.

G64720260401999999990000130850000000000000000000000000000000000000000000000

Auxiliary master fields are preserved as raw scaled values. The linked layout calls them zero-filled, but this edition contains non-zero values. They are not presented as final dollar fees or PDF units.

FieldRaw / scale 10,000
provider00001308500 / 130.85
assistant00000000000 / 0
specialist00000000000 / 0
anaesthetist00000000000 / 0
non anaesthetist00000000000 / 0
Explanation

AI-generated. Unreviewed.

This is the technical component for continuous ECG monitoring recording of 14 or more days, under Electrocardiography, Continuous ECG Monitoring (e.g. Holter), Level 1.

Watch out for

Only eligible for payment once per 30 day period per patient. The source excerpt is incomplete and also refers to using multiples of lesser time duration codes and to external cardiac loop recording devices.

Sources and updates
Fee master effective October 1, 2026Schedule effective July 1, 2026Source versions and changes